The new dimensionP E R F O R M A N C E , F R E E D O M , S I M P L I C I T YA global solution for dental implantologyPROSTHETIC RANGE OVERVIEWFEDP
10AESTHETIC TITANIUM ABUTMENTSw Single-unit or multiple-unit restorations.w 56 components available.w Aesthetic abutment shoulder.w Tulip-shaped gingi
GE11Gingival height 4.5 mm aesthetic TITANIUM abutments havea specifi c gingival profi le to be used in the following situations:w Gingival height of 4.
1212AESTHETIC ZIRCONIA ABUTMENTSw Single-unit restorationin the anterior region.w Biocompatible zirconia.w Aesthetic abutment shoulder.w Three-lobe in
GE1313STANDARD TITANIUM ABUTMENTSw Single-unit or multiple-unit restorations.w 36 components available.w Supplied Q for an immediate placement: -
14w Without three-lobe indexation. w Coronary height 6 mm.w Analogs and transfers for standard TITANIUM abutment-level impression taking: cf page
GE15TITANIUM TEMPORARY ABUTMENTSw Temporary single-unitor multiple-unit restoration.w Retention grooves.w With three-lobe indexation.w Supplied Q.w Re
16GOLD CAST-ON ABUTMENTSw CERAMICOR or PIVOSYL.w Single-unit or multiple-unit cement-retained restoration.w Single-unit screw-retained prosthesis.w Wi
GE17TRY-IN ABUTMENTS FOR CEMENT-RETAINED PROSTHESISTRY-IN ABUTMENTS FOR AXIOM® REG AND AXIOM® PXAngulation (ά)Gingival height (GH)Article number Pictu
18SCREW-RETAINED PROSTHESIS FOR AXIOM® REG/PXFor single-unit, multiple-unit or full-arch restorationw Multiple-unit or full-arch restoration:Rang
GE19Components Article number PicturesPROSTHETICPARTS ON STRAIGHTCONICAL ABUTMENTSTitanium temporary coping OPSC200Titanium protective cap(supplied Q
2Axiom® prosthetic range overviewAxiom® concept, the new dimension Morse tapered internal connection Management of the emerg
20w Multiple-unit and full-arch restoration on angulated implants.w With or without three-lobe indexation.w Supplied Q.w Threaded gripper wrench Art.
GE21Components Article number PicturesANGULATED CONICAL ABUTMENT-LEVEL IMPRESSION TAKINGPick-upor Pop-intechniquePick-up abutment transferSupplied wi
22TRY-IN ABUTMENTS FORSCREW-RETAINED PROSTHESISw The emergence profi le is the same as for the angulated abutments.w Available in indexed or non-indexe
GE23Introducing a ring bonded between the straightconical abutment and the framework cast by thelaboratory, the Pacifi c system ensures the passive fi t
24OVERDENTUREFor full-arch prosthesisCement-retained prosthesisScrew-retainedbar restorationScrew-retained prosthesisSingle-unitrestorationMultiple-un
GE25LOCATOR® ATTACHEMENTCH = 1.6 mmGHØ 4 mmSTABILIZATION OF FULL-ARCH PROSTHESIS> Can be used with 2 implants with angulation < 20°.Gingival hei
26SIMEDA® PROSTHESIS> Single-unit, multiple-unit and complete denture restorations.> Cement-retained or screw-retained restorations.> Large
B272 joursIMPLANT-SUPPORTED RESTORATIONSIllustration Titanium Zirconia CoCr**Machi-ningCoCr**DMLSCustomized abutmentSimeda® AbutmentSina Z- -Screw-re
28RECOMMENDED INSERTION TIGHTENING TORQUE FOR PROSTHETIC COMPONENTSFor Axiom® 2.8 components, please refer to page 32. Components Tightening TorqueCov
GE29PROSTHETIC INSTRUMENTSAXIOM® REG/PXCOMMON PROSTHETIC KITArt. Nb. IN MOD OPPArt. Nb. IN MOD OPPArt. Nb.UNIVERSAL TORQUE WRENCH TORQ CONTROL®Art. Nb
A T H E N E W D I M E N S I O N 3AXIOM® PROSTHETIC RANGE OVERVIEWA solution for any kind of prosthetic restoration: w single-unit, multiple-u
30PROSTHETIC COMPONENTS FOR AXIOM® 2.8Screw-retainedbar restorationScrew-retained prosthesisMultiple-unitrestorationProsthetic solutionsScrew-retained
B31AXIOM® 2.8THE INCISIVE CHOICE !Single-unit restoration of the incisor region in cases presentinga restricted mesiodistal space.CALIBRATED IMPACTING
32PROSTHETIC PARTS FOR AXIOM® 2.8NEW !ComponentsGingival height (GH)Article number PicturesHealing plug1.0 mm OPHS2102.5 mm OPHS2204.0 mm OPHS2405.5
B33PERMANENT ABUTMENTS IMPACTED WITH THE SAFE LOCK®For a mastered andcalibrated impactingwith the SAFE LOCK®5IMPACTIONSComponents Article number Pict
34Angulation (ά)Gingival height (GH)Article number PicturesStraight 0°1.0 mm OPAF2102.5 mm OPAF2204.0 mm OPAF2405.5 mm OPAF2507°1.0 mm OPAF2112.5 mm O
A T H E N E W D I M E N S I O N 35LIST OF MATERIALS (EXCEPTED SIMEDA® PROSTHESIS)Composants MatériauxImplants Axiom® REG/PX/2.8Grade V medical ti
2237 Avenue André Lasquin74700 Sallanches - FrancePhone +33 (0)4 50 58 02 37 Fax +33 (0)4 50 93 78 60 www.anthogyr.comsimeda®customized
4AXIOM® CONCEPT, THE NEW DIMENSIONSTABLE, STRONG ANDHERMETIC CONNECTIONGRADE V MEDICAL TITANIUMTHREADED AND SAND-BLASTED NECKBCP® OSSEO-CONDUCTIVESUR
A T H E N E W D I M E N S I O N 5Ø 3.4 mmArt. Nb.8 mm10 mm12 mm14 mm16 mm18 mmOP34080OP34100OP34120OP34140OP34160OP34180Ø 3.4 mmArt. Nb.8 mm10 mm
6HEALING SCREWSw Supplied Q for single-use.w Low coronary height (1 mm) available for placement under removable prosthesis.Ht. 0.75 Ht. 1.5 Ht. 2.
GE7IMPRESSION TAKING TECHNIQUESw Impression taking technique restricting intra-oral handlings.w Standard titanium abutments are supplied sterile (Cf.
8Screw-retainedbar restorationScrew-retained prosthesisOverdentureFull-archrestorationProsthetic solutionsScrew-retained prosthesisGold cast-onabutmen
GE9A WIDE CHOICE OF CEMENT-RETAINED ABUTMENTSAESTHETIC TITANIUM ABUTMENTSw Straight or angulated 7°, 15°, 23°.w 4 diameters.w 5 gingival heights.w Aes